Mechanisms of Electron-Induced Single-Event Upsets in Medical and Experimental Linacs
2018
In this paper, we perform an in-depth analysis of the single-event effects observed during testing at medical electron linacs and an experimental high-energy electron linac. For electron irradiations, the medical linacs are most commonly used due to their availability and flexibility. Whereas previous efforts were made to characterize the cross sections at higher energies, where the nuclear interaction cross section is higher, the focus of this paper is on the complete overview of relevant electron energies. Irradiations at an electron linac were made with two different devices, with a large difference in feature size. The irradiations at an experimental linac were performed with varying en…
Uso della spettroscopia ESR per la caratterizzazione di composti fenolici irradiati con fasci clinici di fotoni ed elettroni
2016
In the last decades several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. ESR is a spectroscopic method for investigating the structure and dynamics of such paramagnetic species. Free radicals are known to be produced when a compound is irradiated with ionizing radiations. The concentration of radiation-induced free radicals is proportional to the energy released inside in the medium and this allows for dosimetric measurements through ESR technique which able to quantitatively determine the radical concentration. The use of alanine as a dosimetri…
Misure di colore su film radiocromici: nuove frontiere per la dosimetria
2013
Electronic Design for a Bleeding Detector to be Used in Intraoperative Radiotherapy Applications
2021
An electronic design for a bleeding detector used with mobile linac during intraoperative radiotherapy (IORT) is presented. It consists on a readout circuit based on a De Sauty Bridge and a wireless power supply using a supercapacitor. The goal is the measurement of the height of fluid present in the applicator in order to avoid a misadministration dose during the irradiation process. A minimum measurement height of 5 mm is required by clinic to be confident with the selected radiation dose. The measurement circuit uses a capacitive sensor which detects variations lower than 0.1 pF. The readout circuit converts dynamic capacitance variation from the bleeding detector into an analog voltage …
Nuovi gel di Fricke ad alta sensibilità e bassa diffusione per dosimetria 3D tramite MRI
2017
One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiationsensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gel). In this work Fricke gel dosimeters produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GT…
Experimental investigations of the hypernucleus $_Λ^4$H
2015
International audience; Negatively charged pions from two-body decays of stopped _Lambda^4H hypernuclei were studied in 2012 at the Mainz Microtron MAMI, Germany. The momenta of the decay-pions were measured with unprecedented precision by using high-resolution magnetic spectrometers. A challenge of the experiment was the tagging of kaons from associated K^+∧ production off a Be target at very forward angles. In the year 2014, this experiment was continued with a better control of the systematic uncertainties, with better suppression of coincident and random background, improved particle identification, and with higher luminosities. Another key point of the progress was the improvemen…
Sensibilità e stabilità dei dosimetri gel di tipo Fricke esposti ai fotoni nel range clinico in funzione della concentrazione di ferro: 3D MRI ed app…
2014
IRIDE: Interdisciplinary research infrastructure based on dual electron linacs and lasers
2014
This paper describes the scientific aims and potentials as well as the preliminary technical design of RUDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity "particles factory", based on a combination of high duty cycle radio-frequency superconducting electron linacs and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of sci…
Design, construction and performance of the energy compressing system of the Mainz 300 MeV electron linac
1973
Abstract For the sake of better energy resolution of the 300 MeV electron linac of Mainz university a system has been built which transforms a sharply bunched beam of poor energy resolution into a beam of sharply defined energy, while its bunches are smeared out. The system is described, its design philosophy and some essential construction details are given. The operating experience of the last 6 months since completion of the system is communicated.
Measurement of the parity violating asymmetry in the quasielastic electron-deuteron scattering and improved determination of the magnetic strange for…
2016
A new measurement of the parity-violating asymmetry in the electron-deuteron quasielastic scattering for backward angles at $⟨{Q}^{2}⟩=0.224\text{ }\text{ }{(\mathrm{GeV}/c)}^{2}$, obtained in the A4 experiment at the Mainz Microtron accelerator (MAMI) facility, is presented. The measured asymmetry is ${A}_{PV}^{d}=(\ensuremath{-}20.11\ifmmode\pm\else\textpm\fi{}0.8{7}_{\mathrm{stat}}\ifmmode\pm\else\textpm\fi{}\phantom{\rule{0ex}{0ex}}1.0{3}_{\mathrm{sys}})\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$. A combination of these data with the proton measurements of the parity-violating asymmetry in the A4 experiment yields a value for the effective isovector axial-vector form facto…