Search results for " LINAC"

showing 10 items of 17 documents

Mechanisms of Electron-Induced Single-Event Upsets in Medical and Experimental Linacs

2018

In this paper, we perform an in-depth analysis of the single-event effects observed during testing at medical electron linacs and an experimental high-energy electron linac. For electron irradiations, the medical linacs are most commonly used due to their availability and flexibility. Whereas previous efforts were made to characterize the cross sections at higher energies, where the nuclear interaction cross section is higher, the focus of this paper is on the complete overview of relevant electron energies. Irradiations at an electron linac were made with two different devices, with a large difference in feature size. The irradiations at an experimental linac were performed with varying en…

010302 applied physicsNuclear and High Energy PhysicsMaterials scienceta114010308 nuclear & particles physicselectronsElectron linacElectronhiukkaskiihdyttimetelektronitparticle accelerators01 natural sciencesLinear particle acceleratorNuclear physicsNuclear interactionradiation physicsCross section (physics)säteilyfysiikkaNuclear Energy and Engineering0103 physical sciencesElectrical and Electronic EngineeringEvent (particle physics)IEEE Transactions on Nuclear Science
researchProduct

Uso della spettroscopia ESR per la caratterizzazione di composti fenolici irradiati con fasci clinici di fotoni ed elettroni

2016

In the last decades several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. ESR is a spectroscopic method for investigating the structure and dynamics of such paramagnetic species. Free radicals are known to be produced when a compound is irradiated with ionizing radiations. The concentration of radiation-induced free radicals is proportional to the energy released inside in the medium and this allows for dosimetric measurements through ESR technique which able to quantitatively determine the radical concentration. The use of alanine as a dosimetri…

ESR EPR Dosimetry Electron beam LinacSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Misure di colore su film radiocromici: nuove frontiere per la dosimetria

2013

Film radiocromici Dosimetria Colorimetria LINACSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Electronic Design for a Bleeding Detector to be Used in Intraoperative Radiotherapy Applications

2021

An electronic design for a bleeding detector used with mobile linac during intraoperative radiotherapy (IORT) is presented. It consists on a readout circuit based on a De Sauty Bridge and a wireless power supply using a supercapacitor. The goal is the measurement of the height of fluid present in the applicator in order to avoid a misadministration dose during the irradiation process. A minimum measurement height of 5 mm is required by clinic to be confident with the selected radiation dose. The measurement circuit uses a capacitive sensor which detects variations lower than 0.1 pF. The readout circuit converts dynamic capacitance variation from the bleeding detector into an analog voltage …

FluidsMaterials scienceIntraoperative radiotherapybleeding detectorCapacitive sensingDetectorDe Sauty bridgecapacitive sensorLinearityCapacitive sensorsDetectorsRepeatabilityApplicatorsmobile linacsCapacitanceSignalLinear particle acceleratorBridge circuitswireless supplyElectrical and Electronic EngineeringHemorrhagingInstrumentationVoltageBiomedical engineering
researchProduct

Nuovi gel di Fricke ad alta sensibilità e bassa diffusione per dosimetria 3D tramite MRI

2017

One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiationsensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gel). In this work Fricke gel dosimeters produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GT…

Fricke Gel Dosimetry LINAC Dose Dosimetria Radioterapia Diffusione MRISettore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Experimental investigations of the hypernucleus $_Λ^4$H

2015

International audience; Negatively charged pions from two-body decays of stopped _Lambda^4H hypernuclei were studied in 2012 at the Mainz Microtron MAMI, Germany. The momenta of the decay-pions were measured with unprecedented precision by using high-resolution magnetic spectrometers. A challenge of the experiment was the tagging of kaons from associated K^+∧ production off a Be target at very forward angles. In the year 2014, this experiment was continued with a better control of the systematic uncertainties, with better suppression of coincident and random background, improved particle identification, and with higher luminosities. Another key point of the progress was the improvemen…

Lambda: hypernucleusQC1-999Nuclear TheoryAstrophysics[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencestagged beamParticle identificationpi-010305 fluids & plasmasNuclear physicsMomentumMainz LinacPionCoincidentberyllium: target0103 physical sciencesCalibration010306 general physicsNuclear ExperimentMicrotronPhysicsSpectrometerPhysicspi: decayresolutionsuppressionHypernucleusmagnetic spectrometerKmicrotronhydrogenmomentum: calibrationbackground: randomHigh Energy Physics::Experimentluminosity: highparticle identification
researchProduct

Sensibilità e stabilità dei dosimetri gel di tipo Fricke esposti ai fotoni nel range clinico in funzione della concentrazione di ferro: 3D MRI ed app…

2014

MRI Dosimetria LINAC FrickeSettore FIS/01 - Fisica SperimentaleNMR; MRI Dosimetria LINAC FrickeSettore MED/36 - Diagnostica Per Immagini E RadioterapiaNMRSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

IRIDE: Interdisciplinary research infrastructure based on dual electron linacs and lasers

2014

This paper describes the scientific aims and potentials as well as the preliminary technical design of RUDE, an innovative tool for multi-disciplinary investigations in a wide field of scientific, technological and industrial applications. IRIDE will be a high intensity "particles factory", based on a combination of high duty cycle radio-frequency superconducting electron linacs and of high energy lasers. Conceived to provide unique research possibilities for particle physics, for condensed matter physics, chemistry and material science, for structural biology and industrial applications, IRIDE will open completely new research possibilities and advance our knowledge in many branches of sci…

Nuclear and High Energy PhysicsHigh energySC Linac;Neutron source;FEL;Compton source;Advanced accelerators concepts;Particle physicsSettore FIS/07 - FISICA APPLICATA (A BENI CULTURALI AMBIENTALI BIOLOGIA E MEDICINA)Advanced accelerators conceptTechnical designNOAdvanced accelerators conceptsParticle physicSC Linac; FEL; Particle physics; Neutron source; Compton source; Advanced accelerators conceptsInstrumentationFELPhysicsSC LinacSettore FIS/01 - Fisica SperimentaleAdvanced accelerators concepts; Compton source; FEL; Neutron source; Particle physics; SC Linac; Instrumentation; Nuclear and High Energy PhysicsParticle physicsAdvanced accelerators concepts; Compton source; FEL; Neutron source; Particle physics; SC Linac; Nuclear and High Energy Physics; InstrumentationCompton sourceNeutron sourceWide fieldSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Dual (category theory)Free Electron LaserAdvanced accelerators concepts Compton source FEL Neutron source Particle physics SC LinacAdvanced accelerators concepts; Compton source; FEL; Neutron source; Particle physics; SC Linacadvanced accelerators concepts; particle physics; sc linac; compton source; fel; neutron sourceneutron sourcefree electron lasersSystems engineeringFactory (object-oriented programming)Free electron laser
researchProduct

Design, construction and performance of the energy compressing system of the Mainz 300 MeV electron linac

1973

Abstract For the sake of better energy resolution of the 300 MeV electron linac of Mainz university a system has been built which transforms a sharply bunched beam of poor energy resolution into a beam of sharply defined energy, while its bunches are smeared out. The system is described, its design philosophy and some essential construction details are given. The operating experience of the last 6 months since completion of the system is communicated.

Nuclear physicsPhysicsBunchesResolution (electron density)Physics::Accelerator PhysicsElectron linacGeneral MedicineEnergy (signal processing)Beam (structure)Nuclear Instruments and Methods
researchProduct

Measurement of the parity violating asymmetry in the quasielastic electron-deuteron scattering and improved determination of the magnetic strange for…

2016

A new measurement of the parity-violating asymmetry in the electron-deuteron quasielastic scattering for backward angles at $⟨{Q}^{2}⟩=0.224\text{ }\text{ }{(\mathrm{GeV}/c)}^{2}$, obtained in the A4 experiment at the Mainz Microtron accelerator (MAMI) facility, is presented. The measured asymmetry is ${A}_{PV}^{d}=(\ensuremath{-}20.11\ifmmode\pm\else\textpm\fi{}0.8{7}_{\mathrm{stat}}\ifmmode\pm\else\textpm\fi{}\phantom{\rule{0ex}{0ex}}1.0{3}_{\mathrm{sys}})\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$. A combination of these data with the proton measurements of the parity-violating asymmetry in the A4 experiment yields a value for the effective isovector axial-vector form facto…

Particle physicsacceleratorparity: violation: asymmetrymedia_common.quotation_subjectLattice field theoryisovectorelectron deuteron: inelastic scatteringpolarized beamElectron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]form factor: axial-vector01 natural sciencesAsymmetryMainz Linac0103 physical sciencesdeuterium: targetradiative correctionelectron: beam010306 general physicsmedia_commonPhysicsQuasielastic scatteringIsovector010308 nuclear & particles physicsScatteringbackgroundlattice field theoryParity (physics)helicityanapoleHelicityelectron deuteron: scatteringexperimental results
researchProduct